The operational choice begins with pressure. Decompression sickness occurs when dissolved gases form bubbles in blood and tissue; during a spacewalk, a suit operates at lower pressure than the spacecraft cabin. NASA describes combining habitat conditions, suit pressure and breathing procedures before exposure to reduce the body's nitrogen load. [S1]
A patent foramen ovale (PFO) is a persistent opening between the heart's upper chambers. NASA says bubbles can pass through it from the venous to the arterial side, bypassing normal lung filtration. In extreme, high-risk exposures, the assessment says excluding people with a PFO or treating it may slightly reduce overall risk but does not make that risk zero; other physiological factors can also contribute. [S1]
For ground engineering tests, the assessment recommends the same treatment capability as for research protocols, including a treatment chamber immediately beside the testing area. That puts the emphasis on how a test is prepared and supported, rather than relying on a screening decision alone. [S1]
Source documents
- Assessment of PFO as Related to DCS in the Spaceflight Environment and During Ground Testinghttps://www.nasa.gov/organizations/ochmo/assessment-of-pfo-as-related-to-dcs-in-the-spaceflight-environment-and-during-ground-testing/